➩ Product Advantages
With a generation efficiency of 0.35 , the NPG100 converts fuel into usable power at a rate that outperforms many conventional generators. Its optimized gas consumption—rated at 10286±5% kJ/kW·h—minimizes fuel waste, directly lowering operational costs. For businesses and facilities seeking long-term savings, this efficiency translates to significant reductions in energy expenditure over time.
Beyond efficient gas usage, the generator boasts an oil consumption of ≤1.5g/kW·h, ensuring minimal maintenance-related expenses. This low oil requirement reduces both the frequency of refills and the overall cost of upkeep, making it an economical choice for continuous or frequent use.
Despite its powerful output, the NPG100 features a space-saving structure with overall dimensions of 3.0×1.2×1.7m and a weight of 2.4t. This compact footprint allows easy installation in diverse settings, from tight industrial spaces to commercial buildings and off-grid locations, without compromising on performance.
Natural gas as the primary fuel significantly reduces emissions compared to diesel alternatives, helping users meet strict national and international environmental standards. Combined with low noise levels, it is suitable for areas where environmental compliance and community comfort are priorities.
➩ Technical Parameters
| Gas generator set parameters | |
| Rated power(kW) | 1500-2000 |
| Rated speed (rpm) | 1000 |
| Rated voltage (V) | 10500 |
| Frequency(Hz) | 50 |
| Power factor | 0.8 lagging |
| Number of phase and connection | Three phases,star shape |
| Generation efficiency | About 42% |
| Gas consumption (kJ/kW ·h) | 8570±5% |
| Oil consumption(g/kW ·h) | ≤0.6 |
| Noise (dBA) | 92 |
| Continuous power | 80%-90% |
| Weight (kg) | 26000 |
| Overall dimension(Length×Width×Height)m | 7.2×2.5×2.5 |
| Cooling mode | Semi-open or closed,engine double temperature forced cooling |
| Overhaul period | >30000 h |
| Design life | more than 25 years |
| 1.Engine technical parameters | |
| Engine type | 20V190G |
| Rated speed (rpm) | 1000 |
| Number of cylinders | 20 |
| Cylinder type | V-Shape |
| Bore (mm) | 190 |
| Stroke (mm) | 230 |
| Displacement(L) | 130 |
| Exhaust temperature(C) | ≤530 |
| Gas inlet pressure (kPa) | 300-400 |
| Lubricating oil temperature(℃) | ≥70 |
| Start Method | Electric starting |
| 2.Generator parameters | |
| Rated capacity (power)kVA | 1875-2500 |
| Rated voltage(V) | 10500 |
| Connection mode | Three-phases |
| Excitation mode | Brushless self-encouragement |
| Insulation class | F Grade |
| Protection mode | IP23 |
➩ Product Features
Operating at 1500 RPM , the generator ensures a steady 100kW continuous power (standard state) with a rated frequency of 50Hz and rated voltage of 400V. This stability is critical for sensitive equipment in data centers, hospitals, and manufacturing facilities, where power fluctuations can cause significant disruptions.
The integrated gas engine (Model: 6138G-1) features a four-stroke, water-cooled design with 6 cylinders , a bore of 138mm, and a stroke of 150mm , delivering a displacement of 13.5L . Its natural aspiration system (separate air and natural gas intake) and spark plug ignition ensure efficient fuel combustion, while electric control enhances operational precision.
The generator (Model: lFC6283-4-100) offers a rated capacity of 125kVA with a three-phase four-wire connection and 0.8 lagging power factor. Its brushless self-encouragement excitation mode and F Grade insulation guarantee durability, even in demanding conditions, while the IP23 protection mode safeguards against dust and water ingress.
Equipped with a sophisticated control system, the NPG100 supports remote monitoring and automated operation. This feature simplifies maintenance, allows real-time performance tracking, and ensures quick response to power demands or system alerts.
➩ Precautions For Use
1. Regular inspection and maintenance
Regularly carry out a comprehensive inspection of the unit, including the electrical system, cooling system and lubrication system, to ensure that all components are working properly. Especially after high load operation, check the temperature, oil level and voltage of the unit to find and deal with potential problems in time to avoid failure caused by long time without maintenance.
2. Avoid overload operation
In the process of use, make sure the unit does not run over the rated power. Overload operation will not only affect the efficiency of the unit, but may also lead to overheating of the electrical system and shorten the life of the equipment. When in use, closely monitor the load changes and adjust the load in time to ensure that the unit is in a safe operating condition.
3. Environmental adaptability requirements
The 20V190 unit should be installed in a well-ventilated, clean and non-corrosive environment. Avoid placing the unit in a humid, dusty or hot environment, as these factors may affect the operational stability and life of the unit. Make sure there is enough space around the unit for routine inspection and maintenance.
4. Pre-startup Inspection
Before starting the unit, check that all connecting lines are tight, that oil and coolant are sufficient, and that the electrical system is well insulated. The pre-startup inspection can avoid malfunctions during startup and ensure that the unit starts and operates smoothly.
5. Prevent prolonged no-load operation
Prolonged no-load operation of the unit may lead to increased wear and tear of the internal parts, especially for equipment with a low speed. It is recommended not to run the unit under no load for too long, and make sure the unit is running under load for a certain period of time to ensure its performance and efficiency.